<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>✔ Tag-/Nachtmodus justierbar &#8211; Support-Farm | Smart Farming Produktvergleich</title>
	<atom:link href="https://www.support-farm.de/t2600_brightness-adjustment/day-night-mode-adjustable/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.support-farm.de</link>
	<description></description>
	<lastBuildDate>Sun, 22 Mar 2026 12:04:48 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.support-farm.de/wp-content/uploads/2016/06/cropped-ico1-1-32x32.jpg</url>
	<title>✔ Tag-/Nachtmodus justierbar &#8211; Support-Farm | Smart Farming Produktvergleich</title>
	<link>https://www.support-farm.de</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Kverneland IsoMatch Tellus PRO</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/kverneland-isomatch-tellus-pro/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/kverneland-isomatch-tellus-pro/#comments</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Fri, 13 Apr 2018 20:02:43 +0000</pubDate>
				<guid isPermaLink="false">https://www.support-farm.de/?post_type=product&#038;p=2379</guid>

					<description><![CDATA[12" Touchscreen
Automatisches Lenksystem
Section Control
Applikationskarten]]></description>
										<content:encoded><![CDATA[<p>Das IsoMatch Tellus Pro ISOBUS Terminal bietet mit seinem &#8222;Dual screen&#8220; die Möglichkeit zwei ISOBUS-Geräte oder Funktionen gleichzeitig anzeigen und steuern zu können.</p>
<h2> Videos (englisch und weitere Sprachen) </h2>

]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/kverneland-isomatch-tellus-pro/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>Müller-Elektronik Touch 800</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-elektronik-touch-800/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-elektronik-touch-800/#comments</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Mon, 02 Apr 2018 18:58:06 +0000</pubDate>
				<guid isPermaLink="false">https://www.support-farm.de/?post_type=product&#038;p=2359</guid>

					<description><![CDATA[8" Touchscreen
Automatisches Lenksystem
Section Control
Applikationskarten
Genauigkeit bis RTK möglich]]></description>
										<content:encoded><![CDATA[<p>Mit dem Touch 800 ISOBUS-Terminal bietet Müller-Elektronik einen kleinen Bruder vom Touch 1200. Das Touch 800 unterscheidet sich von seinem großen Bruder hauptsächlich in der Baugröße bzw. Displaygröße. </p>
<p><strong>Vorinstallierte Apps (kostenfrei):</strong><br />
ISOBUS-UT (zur Steuerung von ISOBUS-Geräten)<br />
Service (Einstellungen zum Terminal)<br />
Tractor-ECU (Einstellungen zum Traktor)<br />
Virtual ECU (Nutzung von Nicht-ISOBUS-Maschinen)<br />
File Server (Isobus-Geräte können Daten auf dem Terminal ablegen)<br />
Kamera (Kamerabild anzeigen lassen)<br />
ME ODI (mit Ethernet oder Bluetooth verbinden) </p>
<p><strong>Vorinstallierte Testversionen</strong><br />
TRACK-Leader AUTO (automatische Lenkung)<br />
TRACK-Leader TOP kann freigeschaltet werden (automatische Lenkung)<br />
SECTION-Control (GPS-gesteuerte Teilbreitenschaltung)<br />
ISOBUS-TC (Task-Controller = Schnittstelle zwischen Apps wie Section Control und Geräten sowie Schlagkarteien und Terminal)<br />
MULTI-Control (erweitert ISOBUS-TC um Applikationskarten zu einzelnen Dosiergeräten einer Maschine zuzuweisen)<br />
ASD-Protocol (Kommunikation zwischen Terminal und Bordrechner = Terminal sendet Ausbringmenge an Bordrechner sowie Teilbreitenstatus z. B. bei Section Control)</p>
<p><strong>Weiter Apps die freigeschaltet werden können</strong><br />
FIELD-Nav (Navigation zum direkt bis zum Feld, unter Berücksichtigung von Feldwegen und Durchfahrtsbeschränkungen)<br />
Agricon-Plugin (Kopplung mit Sensoren der Firma Agricon wie Yara-N, P3US, P3ALS,&#8230;)</p>
<h2>Videos (deutsch)</h2>

]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-elektronik-touch-800/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>Müller-Elektronik Touch 1200</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-elektronik-touch-1200/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-elektronik-touch-1200/#comments</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Mon, 02 Apr 2018 16:23:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.support-farm.de/?post_type=product&#038;p=2347</guid>

					<description><![CDATA[12,1" Touchscreen
Automatisches Lenksystem
Section Control
Applikationskarten
Genauigkeit bis RTK möglich]]></description>
										<content:encoded><![CDATA[<p>Mit dem Touch 1200 bietet Müller-Elektronik einen echten Allrounder an. Das besondere am Touch 1200 Terminal ist die Möglichkeit zwei ISOBUS Geräte gleichzeitig bedienen zu können (z. B. Front-Tank und Düngerstreuer) sowie die Lenkung deines Traktors zu steuern. Insgesamt kannst du dir 5 Apps auf dem Bildschirm gleichzeitig anzeigen lassen. Im Gegensatz zu seinem kleinen Bruder dem Touch 800 ist das Gehäuse aus Aluminium und die App ISOBUS-TC zum steuern von ISOBUS-Geräten gehört zum Lieferumfang.</p>
<p><strong>Vorinstallierte Apps (kostenfrei):</strong><br />
ISOBUS-UT (zur Steuerung von ISOBUS-Geräten)<br />
Service (Einstellungen zum Terminal)<br />
Tractor-ECU (Einstellungen zum Traktor)<br />
Virtual ECU (Nutzung von Nicht-ISOBUS-Maschinen)<br />
File Server (Isobus-Geräte können Daten auf dem Terminal ablegen)<br />
Kamera (Kamerabild anzeigen lassen)<br />
ME ODI (mit Ethernet oder Bluetooth verbinden)<br />
ISOBUS-TC (Task-Controller = Schnittstelle zwischen Apps wie Section Control und Geräten sowie Schlagkarteien und Terminal)</p>
<p><strong>Vorinstallierte Testversionen</strong><br />
TRACK-Leader AUTO (automatische Lenkung)<br />
TRACK-Leader TOP kann freigeschaltet werden (automatische Lenkung)<br />
SECTION-Control (GPS-gesteuerte Teilbreitenschaltung)<br />
MULTI-Control (erweitert ISOBUS-TC um Applikationskarten zu einzelnen Dosiergeräten einer Maschine zuzuweisen)<br />
ASD-Protocol (Kommunikation zwischen Terminal und Bordrechner = Terminal sendet Ausbringmenge an Bordrechner sowie Teilbreitenstatus z. B. bei Section Control)</p>
<p><strong>Weiter Apps die freigeschaltet werden können</strong><br />
FIELD-Nav (Navigation zum direkt bis zum Feld, unter Berücksichtigung von Feldwegen und Durchfahrtsbeschränkungen)<br />
Agricon-Plugin (Kopplung mit Sensoren der Firma Agricon wie Yara-N, P3US, P3ALS,&#8230;)</p>
<h2>Videos (deutsch)</h2>

]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-elektronik-touch-1200/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>Müller-Elektronik BASIC-Terminal TOP</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-basic-terminal-top/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-basic-terminal-top/#respond</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Tue, 03 Oct 2017 16:23:50 +0000</pubDate>
				<guid isPermaLink="false">http://www.support-farm.de/?post_type=product&#038;p=1766</guid>

					<description><![CDATA[5,7" Display ohne Touch
Automatisches Lenksystem
Section Control
Applikationskarten]]></description>
										<content:encoded><![CDATA[<p>Auch das BASIC-Terminal TOP der Firma Müller-Elektronik wurde einfach und funktionell gehalten. Das BASIC-Terminal TOP ist ein vollwertiges Isobus-Display nach ISOBUS-Norm ISO 11783. Neben dem Einsatz als Isobus-Terminal kann das BASIC-Terminal als Parallelfahrhilfe, für Section-Control und zur Dokumentation eingesetzt werden. Im Gegensatz zum Vorgänger BASIC-Terminal ist die Auftragsverwaltung beim Müller BASIC-Terminal TOP serienmäßig dabei. Das Isobus-Terminal gibt es mit und ohne GSM-Modem für die mobile Datenübertragung. Nur die Version mit GSM-Modem verfügt über Kameraanschlüsse.</p>
<p>Alle verfügbaren Anwendungen sind bereits installiert und fast alle können getestet werden. Einige müssen für die Weiternutzung nach 50 Stunden freigeschaltet werden. Serienmäßig freigeschaltet ist die Anwendung: SERVICE (zur Konfiguration des Terminals), ISOBUS-UT (ISOBUS Maschinensteuerung), ISOBUS-TC (Auftragsverwaltung), Traktor-ECU (Einstellungen zur Sensornutzung und zur Eingabe der Empfängerposition)</p>
<p><strong>Vorinstallierte Testversionen (50 h):</strong><br />
TRACK-Leader (Parallelfahranzeige mit Arbeitsdokumentation Serie), TRACK-Leader TOP kann freigeschaltet werden (automatische Lenkung), SECTION-Control (GPS-gesteuerte Teilbreitenschaltung), VARIABLE RATE-Control (VRC: Applikationskartenverarbeitung aus Shape-Format), FIELD-Nav (Navigation zum direkt bis zum Feld, unter Berücksichtigung von Feldwegen und Durchfahrtsbeschränkungen)</p>
<p><strong>Für Profis:</strong><br />
Kompatible GPS-Receiver benötigen folgende technische Daten:<br />
1,5 V / max. 200mA / NMEA 0183 GPS Standard / Updateraten und Signale: 5 Hz (GPGGA, GPVTG) und 1 Hz (GPGSA,  GPZDA) / 19200 Baud / 8 bit / Parität: nein / Stoppbits: 1 / Flusssteuerung: keine)</p>
<p><strong>Kompatible Bordrechner:</strong><br />
LH5000-Protokoll für teilflächenspezifische Ausbringung z. B. Rauch Quantron A, Quantron E, Quantron E2, Quantron S, Quantron S2, Müller-Elektronik Spraylight.<br />
ASD-Protokoll für teilflächenspezifische Ausbringung und Section-Control z. B.: Amazone Amatron3, Amatron+, Rauch Quantron A, Quantron E, Quantron E2, Müller-Elektronik Spraylight, DRILL-Control</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-basic-terminal-top/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Müller-Elektronik BASIC-Terminal</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-track-basic-terminal/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-track-basic-terminal/#respond</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Wed, 13 Sep 2017 23:51:55 +0000</pubDate>
				<guid isPermaLink="false">http://www.support-farm.de/?post_type=product&#038;p=1551</guid>

					<description><![CDATA[5,7" Display ohne Touch
Automatisches Lenksystem
Section Control
Applikationskarten]]></description>
										<content:encoded><![CDATA[<p>Das BASIC-Terminal der Firma Müller-Elektronik wurde einfach und funktionell gehalten und dient als kosteneffektive Isobus-Lösung. Neben dem Einsatz als Isobus-Terminal kann das BASIC-Terminal als Parallelfahrhilfe, für Section-Control und zur Dokumentation eingesetzt werden. Für eine Auftragsverwaltung kannst du eine Freischaltung bekommen. Beim Müller BASIC-Terminal TOP ist die Auftragsverwaltung Serie.</p>
<p>Alle verfügbaren Anwendungen sind bereits installiert und fast alle können getestet werden. Einige müssen für die Weiternutzung nach 50 Stunden freigeschaltet werden. Serienmäßig freigeschaltet ist die Anwendung: SERVICE (zur Konfiguration des Terminals), ISOBUS-UT (ISOBUS Maschinensteuerung), Traktor-ECU (Einstellungen zur Sensornutzung und zur Eingabe der Empfängerposition), File Server (Isobus-Geräte können Daten auf dem Terminal ablegen), Serial Interface (Serielle Schnittstelle, Kommunikation mit anderem Bordrechner z. B. für Section-Control) das LH5000  Protokoll ist freigeschaltet, das ASD-Protokoll schaltet Dein Händler für Dich bei Bedarf frei. </p>
<p><strong>Vorinstallierte Testversionen (50 h):</strong><br />
TRACK-Leader (Parallelfahranzeige mit Arbeitsdokumentation Serie), TRACK-Leader TOP kann freigeschaltet werden (automatische Lenkung), SECTION-Control (GPS-gesteuerte Teilbreitenschaltung), VARIABLE RATE-Control (VRC: Applikationskartenverarbeitung aus Shape-Format), FIELD-Nav (Navigation zum direkt bis zum Feld, unter Berücksichtigung von Feldwegen und Durchfahrtsbeschränkungen)</p>
<p>Für die ISOBUS-Taskcontroller Auftragsverwaltung ISOBUS-TC gibt es keine Testversion. Mit der Auftragsverwaltung kannst du Aufträge auf dem PC planen und am Terminal aufrufen und abarbeiten.</p>
<p><strong>Für Profis:</strong><br />
Kompatible GPS-Receiver benötigen folgende technische Daten:<br />
1,5 V / max. 200mA / NMEA 0183 GPS Standard / Updateraten und Signale: 5 Hz (GPGGA, GPVTG) und 1 Hz (GPGSA,  GPZDA) / 19200 Baud / 8 bit / Parität: nein / Stoppbits: 1 / Flusssteuerung: keine)</p>
<p><strong>Kompatible Bordrechner:</strong><br />
LH5000-Protokoll für teilflächenspezifische Ausbringung z. B. Rauch Quantron A, Quantron E, Quantron E2, Quantron S, Quantron S2, Müller-Elektronik Spraylight.<br />
ASD-Protokoll für teilflächenspezifische Ausbringung und Section-Control z. B.: Amazone Amatron3, Amatron+, Rauch Quantron A, Quantron E, Quantron E2, Müller-Elektronik Spraylight, DRILL-Control</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-track-basic-terminal/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Müller-Elektronik TRACK-Guide 2</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-track-guide-2/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-track-guide-2/#comments</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Fri, 20 Jan 2017 16:52:41 +0000</pubDate>
				<guid isPermaLink="false">http://www.support-farm.de/vergleich/terminals/mueller-track-guide-2/</guid>

					<description><![CDATA[5,7" Display ohne Touch
Manuelle Parallelfahrhilfe
Section Control
Keine Applikationskarten
]]></description>
										<content:encoded><![CDATA[<p>Das handliche Track Guide 2 Terminal der Firma Müller-Elektronik kann mit und ohne GSM-Modem für die Internetverbindung bestellt werden. Es kann als Isobus-Terminal, als Parallelfahrhilfe, für Section-Control und zur Dokumentation eingesetzt werden. </p>
<p><strong>Verfügbare Freischaltungen im App-Store &#8222;APP &#038; GO&#8220;:</strong><br />
ISOBUS-UT (ISOBUS Maschinensteuerung), ISOBUS-TC (Auftragsbearbeitung), TRACK-Leader (Parallelfahranzeige mit Arbeitsdokumentation Serie), SECTION-Control (GPS-gesteuerte Teilbreitenschaltung), HEADLAND-Management (Vorgewendemanagement); VARIABLE RATE-Control (VRC: Applikationskartenverarbeitung aus Shape-Format), TRACK-Leader TOP (automatische Lenkung), FIELD-Nav (Navigation zum Feld), farmpilot (mobiler Datenaustausch und Logistikmanagement)</p>
<h2>Videos (deutsch)</h2>

]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/mueller-track-guide-2/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>John Deere GreenStar 1800 (GS2)</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/john-deere-greenstar-1800/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/john-deere-greenstar-1800/#comments</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Tue, 11 Oct 2016 03:22:28 +0000</pubDate>
				<guid isPermaLink="false">http://www.support-farm.de/agrar-produktdetails/terminals/john-deere-greenstar-2630-kopie/</guid>

					<description><![CDATA[7" ISOBUS-Display ohne Touch
Automatisches Lenksystem
Section Control
Genauigkeit bis RTK möglich]]></description>
										<content:encoded><![CDATA[<p>Das John Deere GreenStar 1800 Display ist auch bekannt unter dem Namen &#8222;GreenStar 2&#8220; Terminal (GS2). Das Greenstar 2 Terminal kann als Isobus Terminal verwendet werden. Es kann außerdem für ein Lenksystem der Firma John Deere Verwendung finden. Die wichtigsten Punkte können am GreenStar 1800 Terminal dokumentiert werden. Mit zusätzlichen Hardwarekomponenten und teilweise kostenpflichtigen Freischaltungen können Sie die Funktionen erweitern. Z.B. auf die Genauigkeitsstufe SF2 oder das automatische Einschalten der Maschinen am Vorgewende (Section Control) kann das Terminal erweitert werden. </p>
<h2>Videos (englisch)</h2>

]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/john-deere-greenstar-1800/feed/</wfw:commentRss>
			<slash:comments>5</slash:comments>
		
		
			</item>
		<item>
		<title>CCI 100 / 200</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/cci-100-200/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/cci-100-200/#comments</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Thu, 09 Jun 2016 21:18:51 +0000</pubDate>
				<guid isPermaLink="false">http://www.support-farm.de/wordpress/?post_type=product&#038;p=35</guid>

					<description><![CDATA[8,4" Touchscreen
Manuelle Parallelfahrhilfe
Section Control
Applikationskarten]]></description>
										<content:encoded><![CDATA[<p>Das CCI 100 Terminal kann herstellerübergreifend die isobusfähigen Maschinen der Firmen Amazone, Grimme, Krone, Kuhn, Lemken und Rauch steuern. Dabei gilt das Motto: ein Terminal für alle Maschinen. Durch kostenpflichtige &#8222;Apps&#8220; können neben der normalen Bedienung der Maschine auch weitere Funktionen freigeschaltet werden. Parallel Tracking bietet eine optische Lenkhilfe, Section Control schaltet Düngerstreuer, Spritze und Drillmaschine automatisch am Vorgewende. Auch herstellerspezifische Anwendungen gibt es, wie das anzeigen und übernehmen von Düngerstreuereinstellungen aus der Streutabellen-App.</p>
<h2>Videos (deutsch)</h2>

]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/cci-100-200/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>John Deere GreenStar 2630 (GS3)</title>
		<link>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/john-deere-greenstar-2630/</link>
					<comments>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/john-deere-greenstar-2630/#comments</comments>
		
		<dc:creator><![CDATA[Andreas &#124; Support-Farm]]></dc:creator>
		<pubDate>Thu, 09 Jun 2016 21:04:32 +0000</pubDate>
				<guid isPermaLink="false">http://www.support-farm.de/wordpress/?post_type=product&#038;p=30</guid>

					<description><![CDATA[10,2" Touchscreen
Automatisches Lenksystem
Section Control
Applikationskarten
Genauigkeit bis RTK möglich]]></description>
										<content:encoded><![CDATA[<p>Das John Deere Greenstar 2630 Display ist auch bekannt unter dem Namen &#8222;Greenstar 3&#8220; Terminal (GS3). Das Greenstar 3 Terminal bietet die vollen Funktionen für den Einsatz als Isobus Terminal. Es kann für ein vollwertiges Lenksystem, also Lenkhilfe und für Section Control verwendet werden. Auch die Dokumentation kann direkt am 2630 Terminal erledigt werden. Mit zusätzlichen Hardwarekomponenten und teilweise kostenpflichtigen Freischaltungen können Sie die Funktionen erweitern. Über die Genauigkeitsstufen SF1, SF2, RTK und Mobile RTK bis hin zum automatischen Wenden und Einschalten der Maschinen am Vorgewende kann das Terminal stufenweise erweitert werden. Die Freischaltung iTecPro bietet Vollautomatisches Wenden am Vorgewende um die Faktoren Zeit, Kosten und Boden so wenig wie möglich zu belasten. Das John Deere Greenstar 2630 Display unterstützt die Verwendung von Kameras, Ertragskartierung, Applikationskarten und viele weitere Extras.</p>
<h2>Videos (englisch / weitere Sprachen)</h2>

]]></content:encoded>
					
					<wfw:commentRss>https://www.support-farm.de/vergleich/precision-farming-technik/terminals/john-deere-greenstar-2630/feed/</wfw:commentRss>
			<slash:comments>3</slash:comments>
		
		
			</item>
	</channel>
</rss>
